Search
Close this search box.

Unmatched Performance in Liquid Interface Measurements

Unmatched Performance in Liquid Interface Measurements
Many techniques and technologies have been tried with varying degrees of success when attempting to control interface measurements accurately and repeatedly.

Density-based measurements (differential pressure and displacer) are plagued by temperature variations and process variances in specific gravity to make accuracy or repeatability a guarantee. Visual and optical techniques are difficult at best and do not provide assurance that the aqueous phase is not entrained or emulsified in the insulating hydrocarbon phase.

RF Admittance Technology Does the Job

RF Admittance has a unique inherent ability to separate the electrical (Radio Frequency) current flow between a conductive and non-conductive liquid. In fact, this is the only point that RF Admittance is capable of measuring in a liquid/liquid interface. Seen by the RF transmitter as a capacitance value generated by the RF sensor, the highly conductive aqueous liquid phase produces a very large amount of capacitance in comparison to the small amount of capacitance produced by the low dielectric constant of the insulating (hydrocarbon) liquid phase.

The value of RF Admittance becomes apparent in the area that lies between the aqueous and insulating phase known as the “rag” layer or emulsion phase. This layer can be significant and is made up of parts of both the hydrocarbon-insulating phase as well as parts of the conductive aqueous phase. The inherent ability of RF Admittance to accurately track the electrical changeover point between continuous conductive to continuous insulating electrical characteristics means a more reliable and repeatable indication and control in interface measurements.

RF Admittance is Suitable for Many Types of Applications

RF Admittance technology can be applied successfully to any liquid or liquid interfaces that consists of an electrically non-conductive phase over (or under) an electrically conductive phase such as Oil, Water, Solvent/Water, Oil/Acid, or Solvent/Acid.

In a typical liquid or liquid Interface application, RF Admittance can define an electrically conductive phase to be any liquid that has a conductivity greater than 100 micro-siemens.

RF Admittance technology has the inherent capability to provide accurate and repeatable performance in liquid or liquid interface applications, more so than any other process measurement technology. The RF Admittance technology relies solely on the electrical characteristics of the process material and remains unaffected by changes in temperature, pressure, density, and variations in specific gravity.

AMETEK-Drexelbrook offers a wide variety of solutions for both continuous level and point level indication and control of interface measurements, with sensor designs to handle the higher temperatures and pressures and rugged demands that the measurement demands. Level measurement solutions are available for measurement ranges from less than 12 inches to over 100 feet with a wide range of process connections for both vessel and displacer chamber retrofit use.

Share this article

This article is published by

AMETEK is a leading global manufacturer of electronic instruments and electromechanical devices with annual sales of approximately $5 billion. AMETEK has 17,000 colleagues at more than 150 operating locations, and a global network of sales,...

Related Articles