- New Coriolis SystemAccording to AW-Lake, the KEM-CS sensor and KEM-CT transmitter combine accurate, repeatable measurement with touchscreen operation and configurable interfaces.
- Stated PerformanceLiquid mass flow accuracy of ±0.1% of reading and repeatability of ±0.05% of reading, in DN15, DN25 and DN50 sensor sizes.
- IntegrationModbus RTU via RS-485 on the sensor; the transmitter adds up to three configurable interface modules.
AW-Lake, flow instrumentation manufacturer, AW-Lake introduces the KEM-CS Coriolis sensor and KEM-CT Coriolis transmitter, combining accurate, repeatable measurement with convenient touchscreen operation and configurable interfaces. Together, the products provide a flexible solution for chemical processing, batching, blending, dosing, filling, marine fuel monitoring, and other process control applications.
KEM-CS Coriolis Sensor: Accuracy and Compact Integration
The KEM-CS offers liquid mass flow accuracy of ±0.1% of reading and repeatability of ±0.05% of reading, supporting consistent formulation ratios, material usage monitoring, and product quality. Designed for low pressure loss and bidirectional operation, it is available in DN15, DN25, and DN50 sensor sizes with multiple process connection options. Its compact footprint supports integration into OEM equipment, skids, and production systems where space is limited.
KEM-CT Transmitter with 4-Inch Color Touchscreen
The KEM-CT features a fully graphical, 4-inch color touchscreen for viewing measurements, configuring parameters, and accessing diagnostics. A guided setup assistant simplifies commissioning, while selectable display orientation and wall or pipe mounting options provide installation flexibility. The transmitter can be installed up to 100 meters from the sensor, placing measurement information and controls where operators can easily access them.
FAQ – compiled by the Fluid Handling Pro editors
What accuracy does the KEM-CS Coriolis sensor offer?
According to AW-Lake, the KEM-CS offers liquid mass flow accuracy of ±0.1% of reading and repeatability of ±0.05% of reading.
Can the KEM-CS be used without the KEM-CT transmitter?
Yes. Integrated TCA1000 signal processing allows the KEM-CS to operate independently when a separate display is unnecessary. Adding the KEM-CT provides touchscreen operation and expanded interface capabilities.
How far from the sensor can the KEM-CT be installed?
The transmitter can be installed up to 100 meters from the sensor, with wall or pipe mounting options.
Editor’s summary, FAQ and links by the Fluid Handling Pro editors. The article text is by AW-Lake.
Communication Options for Plant Integration
For plant integration, the KEM-CS includes Modbus RTU communication via RS-485 and a configurable frequency output. The KEM-CT expands connectivity through up to three configurable interface modules, with optional 4–20 mA analog outputs and digital inputs and outputs. Users can tailor the system to their application and control requirements.
Standalone Operation and System Diagnostics
Integrated TCA1000 signal processing allows the KEM-CS to operate independently when a separate display is unnecessary. Adding the KEM-CT provides accessible operation and expanded interface capabilities. Sensor status indication and system diagnostics help operators identify operating conditions and respond to process issues.