- SIL 2 CertifiedThe Brooks Instrument MT3809G metal tube variable area flow meter with 4–20 mA analog output is certified as SIL 2 capable under IEC 61508.
- Critical Equipment ProtectionThe certified output can support safety instrumented functions monitoring critical utility flows, helping protect pumps, compressors and other valuable industrial process equipment.
- Supporting DocumentationEngineers can reference the MT3809G Functional Safety Manual and certification documentation to evaluate applicable configurations and requirements.
MT3809G 4–20 mA Analog Output Receives SIL 2 Certification From exida
With SIL 2 certification for the MT3809G’s 4–20 mA output, engineers have another option to add flow measurement into safety instrumented systems that help protect critical assets and support reliable plant operations.
Kostas SklikasGlobal Product Marketing Manager at Brooks Instrument
Brooks Instrument, a world leader in advanced fluid measurement and control technologies, announced that its MT3809G metal tube variable area flow meter with 4–20 mA analog output has received Safety Integrity Level (SIL) 2 certification from exida. The certification expands the instrument’s functional safety capabilities, giving engineers additional flexibility when integrating electronic flow measurement into safety instrumented systems.
The MT3809G previously offered SIL 2 capabilities through mechanical components and alarm configurations. The new certification now extends SIL 2 capability to the 4–20 mA analog output transmitter so the flow measurement signal can be incorporated into applicable safety instrumented functions.
“Maintaining reliable flow of critical utilities, such as seal oil and cooling water, is essential to protecting valuable process equipment,” said Kostas Sklikas, Global Product Marketing Manager at Brooks Instrument.
How Can SIL 2 Flow Measurement Help Protect Critical Equipment?
Industrial equipment often depends on a continuous supply of critical utilities to operate safely and reliably. Variable area flow meters are commonly used to monitor seal oil, cooling water, purge flows and inert gas blanketing in oil and gas, refining, chemical processing, power generation and other process industries.
For example, a loss of seal oil flow can cause serious damage to pumps and compressors, potentially resulting in costly repairs and unplanned downtime. Monitoring these critical flows as part of a properly designed safety instrumented function can help identify unsafe conditions and initiate appropriate protective actions.
With SIL 2 capability available on its 4–20 mA analog output, the MT3809G provides an additional option for adding electronic flow measurement to these safety-related applications.
Frequently Asked Questions
Can the MT3809G be used to monitor critical utility flows in safety instrumented systems?
Yes. Appropriately configured MT3809G flow meters with the certified 4–20 mA analog output can be incorporated into safety instrumented functions for applications such as seal oil, cooling water, purge gas and inert gas flow monitoring. The complete safety function must be designed and evaluated to meet the required safety integrity level.
Does SIL 2 certification apply to all MT3809G flow meters?
No. The certification applies to specified MT3809G configurations with the 4–20 mA analog output manufactured on or after October 27, 2026. MT3809G flow meters manufactured before this date are not covered by the new certification. Customers should consult the Functional Safety Manual to verify applicable configurations and requirements.
Where can I find functional safety documentation for the MT3809G?
The MT3809G Functional Safety Manual and related technical documentation are available through the MT3809 Series product page. Additional background on Safety Integrity Levels is available in Brooks Instrument’s What Is SIL 2? Understanding Functional Safety in Flow Measurement educational resource.
Headings, links and layout by the Fluid Handling Pro editors. The article text, highlights and FAQ are by Brooks Instrument.
What Does the SIL 2 Certification Cover?
The exida certification applies specifically to MT3809G configurations equipped with the 4–20 mA analog output and manufactured on or after October 27, 2026. To achieve the SIL 2 safety certification the device must provide a 4–20 mA output within a specified margin of accuracy.
The certification establishes SIL 2 capability under IEC 61508. However, the suitability of the instrument for a particular application must be evaluated as part of the complete safety instrumented function, including the required architecture, performance and application-specific conditions.
Engineers should reference the Brooks Instrument MT3809G Functional Safety Manual and supporting certification documentation for approved configurations and detailed functional safety requirements.
For additional product specifications, configuration options and documentation, visit the MT3809 Series product page or contact a local Brooks Instrument representative.